Does solar keep working when the power goes out in Victoria?

No, not on its own. A standard solar system is designed to shut down within seconds of a grid outage, and a battery that hasn't been set up for backup shuts down with it.

Solar Victoria puts it plainly: standard solar systems, "with or without a battery, are designed to switch off during a power outage". The reason is safety: crews repairing a line need to know no house is feeding electricity back into it. So every grid-connected inverter (the box that turns the panels' power into household electricity) detects the outage and stops.

Backup doesn't get around that rule. It works by physically disconnecting your home from the grid first, then letting the battery's inverter run your house as its own small, separate supply. Installers call this "islanding", because the house becomes an island with its own power. Solar Victoria notes that backup "depends not just on the battery, but also on the inverter and how the whole system is designed", and that setting it up "may involve additional charges".

If your battery quote doesn't mention a backup device, backup circuits or switchboard work, assume the battery won't run your home in a blackout.

What has to be installed for a battery to back up your home?

Backup needs three things working together: a battery inverter that can run the house without the grid, a device that disconnects your home from the grid when it fails, and switchboard wiring that decides which circuits stay on. There are three broad setups.

Setup What happens in a blackout What it suits
No backup Solar and battery both switch off with the grid Households buying a battery mainly to lower bills
Essential circuits Chosen circuits (for example fridge, lights, wifi, some power points, the gas heater fan) move to a backup section of the switchboard and stay on Most homes that want the basics covered through an outage
Whole home The whole switchboard is disconnected from the grid and supplied by the battery Homes with a large enough battery output and a willingness to manage what runs at once
Three ways a home battery can be wired for a blackoutThree panels. No backup: when the grid fails, the solar and battery switch off and every circuit loses power. Essential circuits: a separate backup board keeps chosen circuits running, such as the fridge, lights, wi-fi, the gas heating fan and some power points, while the oven, air conditioning, electric hot water and EV charger stay off. Whole home: the whole switchboard stays connected, but heavy loads such as the oven, air conditioning, hot water and EV charger only run if the battery has enough output to spare.No backupSolar and battery switch offGridSolar + battery: offFridgeLightsWi-fi and modemGas heating fanSome power pointsOven and cooktopAir conditioningElectric hot waterEV chargerEssential circuitsA backup board feeds chosen circuitsGridSolar + batteryFridgeLightsWi-fi and modemGas heating fanSome power pointsOven and cooktopAir conditioningElectric hot waterEV chargerWhole homeAll circuits, up to its output limitGridSolar + batteryFridgeLightsWi-fi and modemGas heating fanSome power pointsOven and cooktopAir conditioningElectric hot waterEV chargerPowered in a blackoutOnly if the battery has output to spareOff until the grid returns
The same battery gives very different results depending on which circuits are wired to its backup supply. Illustrative.

With essential circuits, an electrician moves selected circuits to a separate backup section or sub-board, so the battery only sees loads it can handle. Anything left off the list stays dark until the grid returns. Whole-home backup keeps every circuit live but doesn't lift the battery's power limit: turn on the oven, kettle and a heater together and the system can overload and shut down.

Some inverters also offer a single backup power point to plug essentials into. One manufacturer's Australian datasheet lists this at 3,000 VA (roughly 3 kW) on one outlet.

Open switchboard enclosure with a battery system controller and circuit wiring

How fast does backup switch on?

Published figures range from milliseconds to seconds. At the quick end, some hybrid inverter manuals list switching in under 10 milliseconds (for example GoodWe's ET series manual), fast enough that most lights and modems carry on. At the slower end, Fronius's datasheet lists about 10 seconds for its full backup mode and up to about 15 seconds for its single backup outlet. Everything goes off briefly, so clocks may need resetting and some devices will restart.

Some systems use a manual changeover switch, which someone has to flip. Know which one you're getting before the first outage.

What decides what your battery can run at once, and for how long?

Two separate numbers: power output and stored energy. Power output, in kilowatts (kW), limits how many appliances can run at the same moment. Stored energy, in kilowatt-hours (kWh), limits how long they can keep running.

More stored energy doesn't raise the power limit. A battery holding 13.5 kWh but limited to 5 kW still can't run a 4.5 kW ducted heat pump and a 2.4 kW kettle together, however full it is.

Continuous backup output varies a lot between single-phase models, and with how each is configured. For example, Tesla's Australian Powerwall 3 datasheet (October 2024) lists nominal output settings of 5, 10 or 11.04 kW with 13.5 kWh of stored energy, while GoodWe's EH series datasheet lists backup outputs of 3,600 to 6,000 VA (roughly 3.6 to 6 kW) depending on the model. The installer sets the figure, so the brochure maximum isn't always what you get.

Typical running power of household loads against an example 5 kW backup limitBar chart of typical running power for household loads against an example 5 kW battery backup limit. Wi-fi, lights, TV, fridge and a gas heater fan each use under 400 W. Split systems use 650 to 1,880 W; kettles, induction cooktop zones and ovens 1,200 to 3,800 W; a 14 kW ducted reverse-cycle system about 4,500 W; and a single-phase EV charger about 7,000 W, above the example limit.01234567 kWWi-fi and modem5–20 WLED lights, 8 × 10 W80 WTV, 50-inch LED120 WFridge, compressor running130 WGas ducted heater fan315 WSplit system, 2.5 kW, heating650–1,480 WSplit system, 7.1 kW, heating1,880 WKettle1.8–2.4 kWInduction cooktop, one zone1.2–2.4 kWElectric oven1.8–3.8 kWDucted reverse-cycle, 14 kW4.5 kWEV charger, single phase7 kWExample backup limit: 5 kWRunning power. Typical figures; check your appliance labels. Start-up surges are higher and not shown.
Typical running power of common household loads against an example 5 kW backup limit. Bars show running watts from manufacturer data and published guides; your appliances' labels give the real figures. Example only.

A fridge, lights, a modem, a TV and a gas heater fan together use well under 1 kW. One kettle or one oven element uses more than all of them combined, and a single-phase EV wall charger, at around 7 kW (SolarQuotes), can exceed a typical backup limit on its own.

A third limit catches people out: start-up surge. Motors in fridges, pumps and older air conditioners draw a brief burst of current as they start, well above their running power. Tesla's datasheet gives its battery's starting limit as "185 locked rotor amps (LRA)", a figure printed on many air conditioner labels, and GoodWe's ET series manual warns against backing up loads with a high starting current, such as high-power water pumps. We check this at design time, because an appliance that runs comfortably on the battery can still trip it when it starts.

How long will a battery last in a Melbourne winter blackout?

Long enough to run the basics through a night, if the battery is reasonably charged when the outage starts and big loads stay off. The answer is a sum: what each appliance uses over the outage, compared with what's in the battery.

A gas-heated home with modest essential circuits gets through the night with energy to spare. Electric heating changes the picture quickly: a split system run at its rated 1.88 kW for eight hours would need about 15 kWh, more than the whole battery holds. Starting charge matters just as much, because a battery that has spent the evening on cooking, heating or exports may hold far less than its full capacity when the outage hits.

Melbourne homes: gas heating, three-phase supply and the circuits you choose

Three local details shape most backup designs here: gas heaters that need electricity, homes on three-phase power, and the list of circuits chosen at design time.

Gas heating still needs power. Solar Victoria notes that "modern gas heating systems have electric fans, and most modern gas hot water systems require electricity for their ignition." Without backup, a gas ducted heater stops in a blackout. The fan is a small load, though. One common ducted gas heater's installation manual lists the fan motor at 315 W on its smaller models and 650 W on larger ones. Putting the heater's circuit, and a gas hot water system that needs power to ignite, on backup is one of the most useful choices a Melbourne household can make.

Three-phase homes need extra thought. Many newer and larger Melbourne homes have three-phase power: electricity arrives on three separate supplies (phases), with circuits spread across them. A single-phase battery may back up only one of the three. Tesla's Australian installation manual for Powerwall 3 (2024 edition) states that "only one phase (L1, L2, or L3) will provide backup during a grid outage", however many units are installed. Appliances that need all three phases, such as some ducted air conditioners and faster EV chargers, stay off. Three-phase hybrid inverters can back up all three phases, but that choice has to be made before installation.

Essential circuits are chosen once. The list of backed-up circuits is set when the switchboard is wired. On site, we ask which appliances and power points matter in an outage: the fridge and freezer, the heater, the modem, a bedroom for someone unwell, a water pump. Adding a circuit later means more switchboard work.

Will solar recharge the battery during a multi-day outage?

It can, if the system is designed for it. While the battery runs the house as an island, panels connected to that system can keep producing and top the battery up during the day. Whether yours can depends on how the panels are connected, and on the weather.

Two common setups don't recharge. Fronius's GEN24 Plus installation guide states that in backup operation "no other inverters or AC sources (e.g., diesel generators) may feed into the emergency power circuit", so an older, separate solar inverter can't help. Tesla's manual similarly requires solar to be on the same phase as the battery if it's to charge it in an outage, which rules out an existing three-phase solar inverter. If you're adding a battery to existing panels, ask how they behave when the grid is down.

Weather is the other limit. The storms behind long outages often bring days of cloud, and a Melbourne winter day produces far less than a summer one, so solar recharging stretches a battery rather than replacing it.

Solar Victoria describes outages in Victoria as "rare", but long ones do happen. On 13 February 2024, storms brought down six transmission towers and, according to the state's Network Outage Review, more than a million customers lost power at some point during the event, with over 531,000 off at the peak. Most were reconnected within days, but more than 3,000 customers were without power for over a week.

Whether a battery helps in a blackout is settled by its wiring long before its size comes into it.

Can a VPP or tariff setting leave your battery empty when the power goes out?

Yes, unless you keep a backup reserve. Batteries that join a virtual power plant (VPP), where a retailer or aggregator draws on many home batteries to support the grid, or that are set to sell energy during price peaks, can be discharged in the evening. If a blackout follows, the battery may hold only its minimum reserve.

Most batteries let you set that reserve: a percentage the battery won't discharge below in normal use, held back for outages. VPP programs commonly keep their own floor. ActewAGL, for example, says its VPP never discharges a battery below 20% during an event. On a 13.5 kWh battery, 20% is 2.7 kWh, which the worked example above shows is not enough for a full winter night. Solar Victoria notes that VPP batteries "are not customised" for backup, even if they can operate during an outage.

There's no single correct reserve: a higher one gives more backup and less day-to-day saving. Some batteries can raise it automatically when storms are forecast. We'd talk the trade-off through with you and set it to suit.

Two points often get confused online. The federal Cheaper Home Batteries Program requires an eligible battery to be VPP capable, but you don't have to join a VPP. Its eligibility rules also say nothing about backup capability. A rebated battery can be installed with or without backup, so ask which one you're being quoted.

What should you ask for when you plan a battery for blackouts?

Ask for backup by name and ask what it covers. Solar Victoria advises telling your installer at the start if you want backup, and notes that "you may also need wiring or electrical upgrades" for it to work (Solar Victoria). Backup is mostly electrical design: the switchboard, the circuits and the phase layout.

  • Is backup included? Look for a named backup or isolation device and switchboard work on the quote, not only a battery.
  • Which circuits are on it? Get the list in writing: fridge, lights, power points, modem, heater fan, hot water ignition, pumps.
  • What's the continuous output in backup? Ask for the kW figure as it will be configured on your system.
  • How does it switch over? Automatic or manual, and roughly how long the gap is.
  • What happens on a three-phase supply? Ask which phase or phases are backed up and which appliances will stay off.
  • Will the solar recharge it in an outage? Especially if you already have panels on a separate inverter.
  • What reserve will it be set to? And how that changes if you join a VPP.
  • Is the switchboard ready? Older boards can need upgrading before backup can be added.

A few safety points sit outside the battery itself. Energy Safe Victoria warns never to power a house by plugging a generator into a wall socket or connecting it to the switchboard, because it can put line workers and neighbours at risk. If a battery has been damaged in a storm or flood, don't switch it on, and have a licensed electrician check it first. And if anyone in the home relies on medical equipment, Solar Victoria says home batteries are typically not appropriate as the primary supply. Register with your electricity retailer for life support and keep a medical backup plan.

Common questions

Will my battery switch on automatically in a blackout?

Only if it has an automatic backup device and backup circuits. A battery without them switches off with the grid. Some systems use a manual changeover switch, which someone has to flip, and switching times range from milliseconds to around 10 to 15 seconds depending on the equipment.

What's the difference between essential-circuit and whole-home backup?

Essential-circuit backup keeps only chosen circuits on, such as the fridge, lights, wifi and heater fan. Whole-home backup keeps every circuit live but is still limited by the battery's kW output, so running several large appliances at once can overload it.

How long will a 13.5 kWh battery last in a blackout?

Comfortably through a winter night if it runs only the basics and starts well charged. A fridge, lights, modem and a gas heater fan might use around 4 to 5 kWh over 12 hours, leaving energy to spare. Electric heating or cooking can use most of the battery in a few hours, and a battery that starts half full has half as much to give.

Will gas ducted heating work in a blackout if I have a battery?

Yes, if the heater's circuit is on backup. Modern gas ducted heaters need electricity for the fan and controls. The fan is a small load (one common model lists 315 W), so it is usually one of the easiest and most useful circuits to back up.

Can a battery run ducted reverse-cycle air conditioning in a blackout?

Sometimes, but it's often the load that breaks the budget. A large ducted system can draw around 4.5 kW while heating, may be three-phase, and can use more energy overnight than a battery holds.

Can I add backup to a battery I already have?

Often, but not always. It depends on whether your inverter supports backup, whether a compatible isolation device exists for it, and whether your switchboard has room.

Does the Cheaper Home Batteries rebate require backup?

No. The federal program requires the battery to be capable of joining a VPP, not to provide backup or to join a VPP. Backup is a design choice you make with your installer, and it may cost extra.

Is a battery a replacement for life-support equipment backup?

No. Solar Victoria says home batteries are typically not appropriate as the primary supply for medical equipment. Register with your retailer for life support and keep a dedicated medical backup plan.

Sources

  1. Solar batteries: what you need to know about backup power, Solar Victoria, updated 3 September 2025.
  2. Power outages and all-electric homes: what you need to know, Solar Victoria, updated 8 September 2025.
  3. Is a solar battery right for your home?, Solar Victoria, accessed 28 October 2026.
  4. Powerwall 3 datasheet (Australia), Tesla, October 2024.
  5. Powerwall 3 with Backup Gateway 2 installation manual (AU), Tesla, 2024.
  6. Fronius Primo GEN24 / GEN24 Plus 3 to 10 kW datasheet (AU), Fronius, accessed 28 October 2026.
  7. Installation guide: GEN24 Plus, Fronius Australia, accessed 28 October 2026.
  8. ET, ET Plus+ and BT series user manual, GoodWe, accessed 28 October 2026.
  9. EH series datasheet (AU), GoodWe Australia, accessed 28 October 2026.
  10. StarPro ducted gas heater installation manual, Brivis, February 2020.
  11. Split system brochure, Daikin Australia, October 2023.
  12. FTXM-Q series databook, Daikin Australia, about 2020.
  13. What household appliances use the most electricity?, ABC News, 3 March 2024.
  14. Fridges and freezers, Energy Rating (Australian Government), accessed 28 October 2026.
  15. Tesla Wall Connector, SolarQuotes, accessed 28 October 2026.
  16. Network Outage Review: final report, Victorian Department of Energy, Environment and Climate Action, 2024.
  17. Who controls your battery in a VPP?, ActewAGL, accessed 28 October 2026.
  18. Cheaper Home Batteries Program: eligibility information, Australian Government Department of Climate Change, Energy, the Environment and Water, accessed 28 October 2026.
  19. Power outages and energy safety, Energy Safe Victoria, accessed 28 October 2026.

We checked every source on . Rebates, tariffs and network rules change; the dates beside each figure show when it applied.